Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 265
Filtrar
1.
J Contemp Dent Pract ; 25(1): 79-84, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514436

RESUMEN

AIM: This study aimed to investigate the effect of modified framework (MF) design on the fracture resistance of IPS e.max Press anterior single crown after thermocycling and cyclic loading. MATERIALS AND METHODS: Two types of IPS e.max Press frameworks were designed (n = 10); standard framework (SF) with a 0.5 mm uniform thickness and MF with a lingual margin of 1 mm in thickness and 2 mm in height connected to a proximal strut of 4 mm height and a 0.3 mm wide facial collar. The crowns were cemented to resin dies, subjected to 5,000 cycles of thermocycling, and loaded 10,000 cycles at 100 N. A universal testing machine was used to load specimens to fracture, and the modes of failure were determined. RESULTS: The mean and standard deviation (SD) of fracture resistance were 219.24 ± 110.00 N and 216.54 ±120.02 N in the SF and MF groups. Thus, there was no significant difference (p = 0.96). Mixed fracture was the most common failure mode in both groups. We found no statistically significant difference between the groups (p = 0.58). CONCLUSION: The MF design did not increase the fracture resistance of IPS e.max Press crown. CLINICAL SIGNIFICANCE: Framework design is an essential factor for the success of all-ceramic restorations and its modification might be regarded as an approach to increase fracture resistance. Furthermore, the modified design was evaluated in metal-ceramic or zirconia crowns while less attention was paid to the IPS e.max Press crowns. How to cite this article: Golrezaei M, Mahgoli HA, Yaghoobi N, et al. The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading. J Contemp Dent Pract 2024;25(1):79-84.


Asunto(s)
Porcelana Dental , Fracaso de la Restauración Dental , Coronas , Cerámica , Ensayo de Materiales , Análisis del Estrés Dental , Diseño Asistido por Computadora , Diseño de Prótesis Dental
2.
BMC Oral Health ; 24(1): 101, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38233771

RESUMEN

TRIAL DESIGN: This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. The aim of this trial was to compare the two-year clinical performance of partial indirect restorations fabricated from CAD/CAM nano-hybrid composite and ceramic lithium disilicate blocks using the modified USPHS criteria. METHODS: In two parallel groups (n = 50 restorations), fifty participants having mutilated vital teeth with a minimum of two remaining walls were randomly enrolled in this trial and received indirect restorations of either nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland) or Lithium Disilicate (IPS Emax CAD). The restorations were assessed using modified USPHS criteria by two independent blinded assessors at baseline, six months, one-year and two years follow-up visits. Categorical and ordinal data were presented as frequencies and percentages. Categorical data were analyzed using the chi-square test. Ordinal data were analyzed using the Mann-Whitney U test for intergroup comparisons and Freidman's test followed by the Nemenyi post hoc test for intragroup comparisons. Numerical data were presented as mean and standard deviation values. They were analyzed for normality using the Shapiro-Wilk test. Data were found to be normally distributed and were analyzed using the independent t-test. The significance level was set at p ≤ 0.05 within all tests. RESULTS: Forty-eight participants received the allocated intervention and completed the follow-up periods. There was a statistically significant difference between both tested materials for all USPHS criteria regarding Marginal integrity and Marginal discoloration at six-months Follow-up, but with no statistically significant difference at one- and two-year follow-up. CONCLUSIONS: Both materials showed an acceptable, successful clinical performance along the two-years follow-up period. CLINICAL RELEVANCE: The CAD/CAM nano-hybrid composite blocks are as reliable as Lithium disilicate for restoring mutilated vital teeth.


Asunto(s)
Porcelana Dental , Incrustaciones , Humanos , Cerámica , Diseño Asistido por Computadora , Materiales Dentales , Ensayo de Materiales
3.
Clin Exp Dent Res ; 10(1): e820, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38044540

RESUMEN

OBJECTIVES: The objective of this in vitro study was to evaluate the shear bond strength between the ceramic veneer and additively manufactured titanium with different surface treatments, and to compare with milled titanium. Also, to characterize the surface and the presence of an α-case layer of additively manufactured and milled titanium. MATERIAL AND METHODS: Sixty additively manufactured titanium grade 23, and 20 milled titanium grade 4 cylindrical specimens were divided into four groups based on surface treatments, air-particle abrasion and grinding. After ceramic veneering half of each group were thermocycled. The bond strength was analyzed using a shear bond strength test. The surfaces were analyzed using interferometry and scanning electron microscopy. RESULTS: The grinding procedure and air-particle abrading pressure had no significant effect on the shear bond strength (p = .264 and p = .344). Thermocycling showed a tendency towards an effect but not significant (p = .052). The group with the highest air-abrading pressure showed the highest surface roughness. No presence of an α-case layer was detected in any of the groups. CONCLUSION: Additively manufactured titanium grade 23 may be veneered with ceramics without prior grinding of the surfaces.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Porcelana Dental/química , Titanio , Propiedades de Superficie , Ensayo de Materiales , Cerámica/química
4.
Dent Res J (Isfahan) ; 20: 88, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37810452

RESUMEN

Background: This study aims to investigate the color stability of feldspathic porcelains with different concentrations of silver nanoparticles (AgNPs). Materials and Methods: In this experimental study, feldspathic porcelain disks with AgNPs of 0 parts per million (ppm), 250 ppm, and 500 ppm were used (sample size = 180). These ceramic discs were subjected to thermocycling in tea, orange juice, and artificial saliva. The optical parameters of disks were measured before and after being immersed in the solutions. Then, the color change (ΔE 00) of the samples was measured by using the CIEDE 2000 formula. The data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post hoc test. The level of significance was determined to be 0.05. Results: The results of the ANOVA test show that there was a significant difference in ΔE 00 (P ≤ 0.05). The maximum ΔE 00 was visible in the samples with AgNPs 0 ppm that were exposed to orange juice, and the minimum ΔE 00 was related to the disks with AgNPs 500 ppm in artificial saliva. Conclusion: Based on the results of this study, adding AgNPs to feldspathic porcelain increases the color stability of the ceramic discs.

5.
Int J Oral Implantol (Berl) ; 16(3): 181-194, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37767614

RESUMEN

PURPOSE: This systematic review aimed to evaluate the medium-term (3-year) overall survival and success rates, marginal bone loss and different biological parameters displayed with one-piece zirconia implants. MATERIALS AND METHODS: Electronic searches were conducted of the MEDLINE (via PubMed), Scopus (Elsevier), Cochrane Library (Wiley) and Web of Science (Clarivate Analytics) databases and manual searching was also performed for relevant articles published up to 14 November 2022. The review included human studies with a minimum of 10 subjects and/or 20 implants and with a follow-up period of at least 3 years after implant placement. RESULTS: Twelve studies met the inclusion criteria and were included for analysis, giving a total of 1,621 one-piece zirconia implants. Eleven studies were included to perform a meta-analysis of survival rates, and six for success rates and marginal bone loss. The survival and success rates at the 3-year follow-up were 94.4% (95% confidence interval 90.4%-98.4%; P < 0.001) and 91.6% (95% confidence interval 84.2%-98.9%; P < 0.001), respectively, and marginal bone loss was 0.231 mm (95% confidence interval 0.190-0.272; P < 0.001). CONCLUSIONS: One-piece zirconia implants appear to be a reliable option for restoring missing teeth, obtaining an implant survival rate of 94.4% and a success rate of 91.6% after a follow-up period of at least 3 years. Moreover, the results showed acceptable rates of marginal bone loss and adequate biological parameters.

6.
Medicina (Kaunas) ; 59(6)2023 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-37374252

RESUMEN

Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers' recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis. A Tukey HSD posthoc test (α = 0.05) was used to determine significant intergroup differences. Results: After surface evaluation of the ceramics, the Ra values of the polishing systems ranked OptraFine (0.41 ± 0.26) < Enhance (1.60 ± 0.54) < Shofu (2.14 ± 0.44) < Astropol (4.05 ± 0.72) < DiaComp (5.66 ± 0.62) < No Polishing (5.66 ± 0.74). Discussion: Composite polishing systems did not provide as smooth surfaces as the ceramic polishing kit for CAD-CAM leucite-reinforced ceramics. Thus, using ceramic polishing systems, polishing leucite ceramics is recommended, whereas composite polishing systems should not be considered as an alternative for use in minimally invasive dentistry.


Asunto(s)
Cerámica , Resinas Compuestas , Humanos , Ensayo de Materiales , Propiedades de Superficie
7.
Eur J Prosthodont Restor Dent ; 31(4): 346-357, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37382351

RESUMEN

PURPOSE: This study evaluated the effect of coating traditional and translucent Y-TZP with an industrial nanometric colloidal silica or glaze before or after sintering on the adhesion of zirconia with various ytrria concentration. MATERIALS AND METHODS: Specimens of Y-TZP with 3% and 5% yttria were subdivided into 5 groups (n=10), according to the coating applied and moment of application (before or after Y-TZP sintering): Control (no coating), Colloidal Silica/Sintering, Sintering/Colloidal Silica, Glaze/Sintering, Sintering/ Glaze. Lithium disilicate (LD) was used as positive control. Except for Y-TZP controls, groups were conditioned with silane before cementation with a self-adhesive resin cement. After 24 hours, the shear bond strength and failure analysis were performed. Also, analysis of specimens' surface was accomplished with SEM-EDX. Kruskal-Wallis and Dunn tests were applied to analyze differences between groups (p⟨0.05). RESULTS: Overall, the worst and best values of shear bond strength test were control and glaze after sintering groups. Different morphological and chemical aspects were observed in SEM-EDX analysis. CONCLUSIONS: Coating Y-TZP with colloidal silica showed unsatisfactory results. In 3Y-TZP, the surface treatment associated with the best adhesion values was the application of glaze after zirconia sintering. However, in 5Y-TZP, glaze application can be performed before or after the zirconia sintering to optimize clinical steps.


Asunto(s)
Recubrimiento Dental Adhesivo , Dióxido de Silicio , Propiedades de Superficie , Dióxido de Silicio/química , Cementación , Circonio/química , Cementos de Resina , Ensayo de Materiales , Itrio/química , Itrio/uso terapéutico , Recubrimiento Dental Adhesivo/métodos , Cerámica/uso terapéutico
8.
BMC Oral Health ; 23(1): 419, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37353807

RESUMEN

PURPOSE: This study aimed to assess the diagnostic accuracy of cone-beam computed tomography (CBCT) and digital intraoral radiography for the detection of proximal caries adjacent to amalgam, e.max porcelain, and metal-ceramic restorations (MCRs). MATERIALS AND METHODS: Parallel intraoral radiographs were obtained from 40 posterior teeth using PSP sensors. To obtain CBCT scans, the teeth were first radiographed alone, and were then positioned next to a tooth with an amalgam restoration, MCR, and e.max porcelain crown, and radiographed again. Two blinded observers scored radiographs using a four-point scale (0: absence of proximal caries, 1: enamel caries, 2: carious lesion extending to the outer half of dentin, 3: carious lesion extending to the inner half of dentin). Tooth sections were made, and the grade of caries was determined under a light microscope at x12 magnification. The sensitivity, specificity, and accuracy of CBCT and intraoral radiographs were then calculated. RESULTS: Artifact-free CBCT scans and intraoral radiographs had the highest diagnostic accuracy (0.826 and 0.657, respectively) while CBCT images of the teeth next to the amalgam restorations (0.526) had the lowest accuracy. The diagnostic accuracy of CBCT images of the teeth next to the porcelain crowns and MCRs was 0.613 and 0.601, respectively. CONCLUSION: Artifact-free CBCT images had higher diagnostic accuracy than intraoral radiography for the detection of all grades of proximal caries. The diagnostic accuracy of CBCT images of teeth adjacent to amalgam, porcelain, and MCRs was lower compared to intraoral radiographs and artifact-free CBCT images.


Asunto(s)
Caries Dental , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Porcelana Dental , Susceptibilidad a Caries Dentarias , Sensibilidad y Especificidad , Radiografía Dental Digital/métodos , Caries Dental/diagnóstico por imagen , Caries Dental/patología , Amalgama Dental
9.
J Mech Behav Biomed Mater ; 143: 105934, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37257313

RESUMEN

The aim of this study was to evaluate the influence of various opacities and thicknesses of lithium disilicate on the degree of conversion (DC) of two resin cements and on their bond strength (BS) to the ceramic. Two hundred and forty ceramic samples of lithium disilicate with high translucency (HT), low translucency (LT), and medium opacity (MO) were obtained from IPS e. max CAD in five different thicknesses. Light-cured and dual-cured resin cements were used for DC (n = 9) and BS (n = 8). Cement samples were light-cured under ceramic samples and analyzed using a Raman confocal spectrometer to determine the DC. For BS, resin cement cylinders were fabricated using ceramic samples which were thsen subjected to a microshear bond strength test. The mean values were provided for statistical analysis. The increase in thickness resulted in a decrease in DC for both cements under all experimental conditions, but only affected the BS of the light-cured cement for the MO ceramic. Comparing the opacities, the most translucent ceramics with particular thicknesses exhibited higher DC values than the less translucent ceramics. The LT and MO ceramics with certain thicknesses exhibited the highest BS values than the HT. The dual-cured cement generally showed highest values in both analyses than the light-cured cement. A thicker and more opaque ceramic material can reduce the DC of the cement. The BS decreases with the increasing thickness of the more-opaque ceramics.


Asunto(s)
Porcelana Dental , Cementos de Resina , Cementos de Resina/química , Ensayo de Materiales , Cerámica/química , Propiedades de Superficie
10.
J Funct Biomater ; 14(4)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37103306

RESUMEN

Tooth reduction guides allow clinicians to obtain the ideal space required for ceramic restorations. This case report describes a novel design (CAD) for an additive computer-aided manufactured (a-CAM) tooth reduction guide with channels that permitted access for the preparation and evaluation of the reduction with the same guide. The guide features innovative vertical and horizontal channels that permit comprehensive access for preparation and evaluation of the reduction with a periodontal probe, ensuring uniform tooth reduction and avoiding overpreparation. This approach was successfully applied to a female patient with non-carious lesions and white spot lesions, resulting in minimally invasive tooth preparations and hand-crafted laminate veneer restorations that met the patient's aesthetic demands while preserving tooth structure. Compared to traditional silicone reduction guides, this novel design offers greater flexibility, enabling clinicians to evaluate tooth reduction in all directions and providing a more comprehensive assessment. Overall, this 3D printed tooth reduction guide represents a significant advancement in dental restoration technology, offering clinicians a useful tool for achieving optimal outcomes with minimal tooth reduction. Future work is warranted to compare tooth reductions and preparation time for this guide to other 3D printed guides.

11.
Dent Mater ; 39(6): 568-576, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37088587

RESUMEN

OBJECTIVE: Feasibility investigation of natural teeth shades replication on dental prosthetics fabricated via functionally graded additive manufacturing (FGAM) using combination of feldspathic porcelain (FP) and yttrium aluminum garnet cerium (Y3Al5O12:Ce, YAG:Ce) as a promising esthetic restoration option. METHODS: Color-graded feldspathic crown fabrication parameter through FGAM method was comprehensively examined from the slurry rheology, cure depth, debinding to sintering temperature. Effect of light absorbent also checked towards overcuring reaction during UV exposure by the shape comparison. Lastly, the flexural bending strength measured following ISO 6872:2015 to assure the applicability. Applying the studied parameter, natural teeth shades then imitated and investigated by alteration of FP and FP + 0.1 wt% YAG:Ce (Y-FP). Generated color across the structure captured through mobile camera, interpreted through the CIELAB coordinate and the gradation confirmed by the color differences (ΔE00) calculated using CIEDE2000 formula. RESULT: Parameter study indicated that 70 wt% of FP slurry with 3 wt% dispersant and 0.2 wt% light absorbent is favored. It produces excellent flowability in our FGAM system with less overcuring justified by edge margin reduction from 95.65° to 90.00° after UV exposure on rectangle shapes masking. The obtain structure also offers adequate flexural bending strength of 106.26 MPa (FP) and 101.36 MPa (Y-FP) after sintering at 780 °C. This validated the materials as class 2 dental prosthetics citing ISO 6872:2015. Color gradation was verified by the yellow b* value reduction (14.8 to -3.33) as it shifted from cervical to incisal area while ΔE00 further affirmed the differences from each segment in comparison with the FP and Y-FP. SIGNIFICANCE: Color gradation was successfully replicated by FP and YAG:Ce composition shift via FGAM technique. This result highlights the potential of FGAM as an alternative for fabricating dental prosthetics with high efficiency and improved esthetic appeal.


Asunto(s)
Porcelana Dental , Estética Dental , Ensayo de Materiales , Porcelana Dental/química , Coronas , Temperatura , Color , Cerámica/química
12.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 108-113, 2023 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-36718697

RESUMEN

OBJECTIVE: To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve. METHODS: Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation. RESULTS: The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05). CONCLUSION: The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.


Asunto(s)
Incisivo , Preparación Protodóncica del Diente , Humanos , Preparación Protodóncica del Diente/métodos , Curva de Aprendizaje , Coronas , Preparación del Diente , Cerámica , Porcelana Dental , Diseño de Prótesis Dental
13.
Braz. dent. sci ; 26(3): 1-12, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1511733

RESUMEN

Objective:This study evaluated the effect of immediate dentin sealing on the marginal adaptation of lithium disilicate overlays with three different types of resin-luting agents: preheated composite, dual-cure adhesive resin, and flowable composite. Materials and Methods: Forty-eight maxillary first premolars of similar size were prepared with a butt joint preparation design. The teeth were separated into two primary groups, each with twenty-four teeth: Group DDS: Delay dentin sealing (non-IDS) teeth were not treated. Group IDS: dentin sealing was applied immediately after teeth preparation. Each group was subsequently separated into three separate subgroups. Subgroups (DDS+Phc, IDS+Phc): cemented with preheated composite (Enamel plus HRi, Micerium, Italy), Subgroups (DDS+Dcrs, IDS+Dcrs): cemented with dual-cured resin cement (RelyX Ultimate, 3M ESPE, Germany) and Subgroups (DDS+Fc, IDS+Fc): Cemented with flowable composite (Filtek supreme flowable, 3M ESPE, USA). Using a digital microscope with a magnification of 230x, the marginal gap was measured before and after cementation at four different locations from each surface of the tooth, and the mean of measurements was calculated and analyzed statistically using the independent t-test, one-way ANOVA test, Bonferroni correction at a significance level of 0.05. Results: The samples that were immediately sealed with dentin bonding agent showed lower marginal gaps than delayed dentin sealing, both pre-and post-cementation for all subgroups, with a statistically significant difference (p˂0.01). The marginal gap was significantly lower in the IDS+Fc (48.888 ±5.5 µm) followed by the IDS+Dcrs group (53.612 ±5.8 µm) and IDS+Phc (79.19 9±6.9 µm) respectively, while the largest marginal gaps were observed in the DDS+Phc group (86.505 ±5.4 µm). Conclusion: Generally, the teeth with IDS showed better marginal adaptation than teeth without IDS. The marginal gap was smaller with flowable composite and dual-cure resin cement than with preheated composite (AU)


Objetivo:Esse estudo avaliou o efeito do selamento imediato da dentina na adaptação marginal de overlays em dissilicato de lítio com três tipos diferentes de agentes de cimentação resinosos: resina composta pré-aquecida, adesivo resinoso dual e resina fluida. Materiais e métodos: Quarenta e oito primeiros pré-molares maxilares com tamanho similar foram preparados com término em ombro. O dente foi separado em dois grupos primários, cada um com vinte e quatro dentes: Grupo DDS: retardado selamento da dentina (non-IDS) dente não foi tratado. Grupo IDS: selamento dentinário foi aplicado imediatamente após a preparação do dente. Cada grupo foi separado de modo subsequente em três subgrupos. Subgrupo (DDS+Phc, IDS+Phc): cimentado com resina pré-aquecida (Enamel plus HRi, Micerium, Italy), Subgrupo (DDS+Dcrs, IDS+Dcrs): cimentado com cimento resinoso dual (RelyX Ultimate, 3M ESPE, Germany) e Subgrupo (DDS+Fc, IDS+Fc): cimentado com resina fluida (Filtek supreme flowable, 3M ESPE, USA). Usando um microscópio digital com magnificação de 230x, o gap marginal foi medido antes e após a cimentação em quatro diferentes localizações de cada superfície do dente e a média das medidas foi calculada e estatisticamente analisada através do uso do teste ANOVA um-fator e teste independente de Tukey e correção Bonferroni com nível de significância de 0,05. Resultado: As amostras que foram imediatamente seladas com agente adesivo dentinário apresentaram menores gaps marginais do que o selamento dentinário retardado, ambos pré e pós cimentação para todos os subgrupos apresentaram diferença estatística significante (p˂0.01). O gap marginal foi significativamente menor para IDS+Fc (48.888 ±5.5 µm) acompanhado do IDS+Dcrs group (53.612 ±5.8 µm) e IDS+Phc (79.19 9 ±6.9 µm) respectividamente, enquanto o maior gap marginal foi observado no grupo DDS+Phc (86.505 ±5.4 µm). Conclusão:Geralmente, o dente com IDS apresentou melhor adaptação marginal do que o dente sem IDS. O gap marginal foi menor com resina fluida e cimento resinoso dual do que com a resina composta pré-aquecida (AU)


Asunto(s)
Cementación , Diseño Asistido por Computadora , Adaptación Marginal Dental , Cementos de Resina , Porcelana Dental
14.
Braz. j. oral sci ; 22: e231377, Jan.-Dec. 2023. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1519248

RESUMEN

The aim of this study was to investigate the influence of the quantity and positioning of feldspathic ceramic specimens inside the furnace on their flexural strength and translucency. The tested hypotheses were that the arrangement of specimens in the furnance would not influence 1) the translucency or 2) the biaxial strength of the porcelain. Methods: Ninety porcelain specimens were made (1.2 mm thickness and 13.5 mm diameter) and assigned into two main groups (n=15): G1 group - 15 firing cycles containing only one specimen each, always at the center of the refractory; and G5 group - 15 firing cycles containing five specimen each, where one specimen was at the center of the refractory and four specimens positioned equidistantly on the periphery. The translucency test was performed using a spectrophotometer, followed by the flexural strength test, according to ISO 6872:2015. T-student test was performed for both the mechanical and optical obtained data. Results: The flexural strength of the porcelain was not affected by the positioning (center x periphery) of the specimens inside the furnace (p =0.08), but the translucency was affected (periphery > center; p =0.009). Regarding to the number of feldspathic ceramic specimens, the biaxial flexural strength was affected (p =0.025), as well as the translucency (p <0.05). Conclusion: A higher quantity of feldspathic ceramic specimens for each firing cycle decreased its biaxial flexural strength and translucency. Also, specimens positioned at the center of the refractory became less translucent than those positioned at the periphery.


Asunto(s)
Humanos , Termodinámica , Porcelana Dental/química , Absorción Fisicoquímica , Resistencia Flexional , Luz , Espectrofotometría , Temperatura , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Fractografía
15.
Mater Today Proc ; 89: 24-29, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-38590583

RESUMEN

Studies have reported challenges of debonding of dental zirconia crowns to from luting cement and prepared teeth. The aim of the study was to explore the application of dental glazing systems for enhancing the bonding of zirconia dental ceramics to luting resin cement. Commercial glaze powder and liquid (Vita Akzent) and experimental mica-based glaze powders were used for the study. X-ray diffraction analysis of the glaze powders (XRD) and Fourier Transform InfraRed Spectroscopy (FTIR) was done on the glaze liquid. Sandblasted sintered dental zirconia (Katana, Noritake) were the control samples. Glazed zirconia samples were coated with commercial glaze and experimental glaze powders which were further etched with 5% hydrofluoric acid. Shear bond strengths of sandblasted and glazed zirconia samples to resin composites were evaluated. XRD of commercial and experimental glaze powders revealed a broad peak confirming the amorphous nature of glass and FTIR analysis of the glaze liquid revealed symmetrical stretching (CH2-CH3) of the alcohol group indicating a mixture of iso-butane and ethanol. Glazed and etched zirconia showed significantly higher shear bond strength to resin cement compared to sand-blasted zirconia. The study confirms the glassy nature of dental glaze powders and the presence of ethanol-based mixtures in the commercial glaze liquid. Glazing systems have the potential to be explored for enhancing the bonding of non-etchable zirconia ceramics to resin cement and tooth substrates.

16.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-971281

RESUMEN

OBJECTIVE@#To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.@*METHODS@#Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.@*RESULTS@#The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).@*CONCLUSION@#The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.


Asunto(s)
Humanos , Preparación Protodóncica del Diente/métodos , Incisivo , Curva de Aprendizaje , Coronas , Preparación del Diente , Cerámica , Porcelana Dental , Diseño de Prótesis Dental
17.
J Clin Med ; 11(21)2022 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-36362777

RESUMEN

BACKGROUND: This systematic review and meta-analysis aimed to evaluate the wear of the antagonist tooth in ceramic restorations. MATERIAL AND METHODS: This study was carried out based on Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) recommendations; it was also registered in PROSPERO (register number: CRD42022316252). Three databases were consulted in the literature search, Embase, Scopus, and Web of Science. The citation searching was conducted by two researchers independently. The clinical studies that evaluated wear in antagonist teeth concerning ceramic restoration were included. Twelve articles were selected after eliminating duplicates ones and applying the inclusion criteria, and two were chosen through citation. Fourteen articles were considered for the qualitative and quantitative analysis (meta-regression and meta-analysis). RESULTS: The mean linear wear of the antagonist tooth in relation to feldspathic was 8.914 µm, for lithium disilicate it was 0.018 µm, and for zirconia it was 0.257 µm. The mean volumetric wear of the antagonist tooth in relation to feldspathic was 0.273 mm3, for hybrid ceramic it was 0.030 mm3, for lithium disilicate it was 0.018 mm3, and for zirconia it was 0.014 mm3. The mean natural tooth wear was 0.7974 µm per month. Tooth wear caused by zirconia at six months was 31.755 µm, at 12 months it was 24.648 µm, and at 24 months it was 20.662 µm. CONCLUSIONS: Feldspathic produces greater wear of the antagonist tooth from ceramic restorations linearly and volumetrically. In addition, zirconia generates the least wear that will decrease over time, and it will be equal to or less than the natural wear in the tooth.

18.
Dent Res J (Isfahan) ; 19: 91, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36426276

RESUMEN

Background: The chemical bond between the metal and the porcelain component is likely to fail in metal-porcelain restorations. This is due to the thick oxide layer that Cr-Co alloys create. This study aimed to investigate the effect of metal conditioner on controlling the oxide layer formed on the surface of the Sintron alloy and the strength of the metal-porcelain bond. Materials and Methods: In this in vitro study, 33 samples were divided into three groups based on surface treatment (n = 11). In all three groups, an oxide layer was created. In the first group, Shofu metal conditioner, in the second group, metal conditioner of Creation, and in the third group, no metal conditioner was applied. All samples were then subjected to 3000 heat cycles between 5° and 55°C with a stop time of 5 s. The specimens were then placed in a universal testing machine for shear bond testing. A force was applied between the alloy and the porcelain by a 5 kN load cell at the speed of 1 mm/min until a fraction occurred. Intergroup comparison was made by the one-way analysis of variance followed by the Tukey's multiple comparisons test (α = 0.05) . Results: The mean shear bond strength of the first group was 34.93 MPa and the mean shear bond strength of the second group was 31.37 MPa. The mean shear bond strength of the first and the second group was significantly higher than the third group (23.37 MPa) (PV < 0.001). Conclusion: The use of metal conditioners between ceramill Sintron alloy and porcelain (Vita VMK MASTER) led to increasing the bond strength.

19.
J Mech Behav Biomed Mater ; 136: 105520, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36341889

RESUMEN

PURPOSE: The aim was to investigate the load bearing capacity of different pressable lithium disilicates cemented as occlusal veneers on molars. MATERIALS AND METHODS: One control group and six test groups were formed consisting of 20 specimens each (n = 20). The six test groups differed in the utilizing pressable lithium disilicate to fabricate occlusal veneers. As a control group, "group Lis", the lithium disilicate with the highest reported flexural strength was used (initial LiSi Press, GC Europe; Leuven, Belgium / flexural strength: 508 MPa). The test groups consisted of other pressable lithium disilicates with lower flexural strength values: "Ema" (IPS e.max press), "Vit" (VITA Ambria), "Liv" (Livento Press), "Amb" (Amber Press), "Mas" (Amber Press Master) and "Ros" (Rosetta SP)". After the preparation of 140 extracted human molars, which included the removal of the central enamel, the specimens were scanned using a desktop scanner. With the aid of a design software, the occlusal veneers were designed in a standardized thickness of 0.5 mm. To fabricate the restorations, all tested materials were processed using heat-pressing technique. All restorations were adhesively cemented. Afterwards, the specimens underwent cyclic fatigue during an aging procedure in a chewing simulator (1'200'000 chewing-cycles, 49 N force, 5-55°C temperature changes). Subsequently, the specimens were statically loaded and the load which was necessary to fracture the specimen (Fmax) were measured. Differences between the groups were compared applying the Kruskal-Wallis (KW) test and the Wilcoxon-Mann-Whitney-Test (WMW: p < 0.05). The two-parameter Weibull distribution values were calculated. RESULTS: The fatigue resistance was 100% for the groups Lis, Vit, Liv, Amb, Mas and Ros, whereas the group Ema showed a fatigue resistance of 95%. The control group Lis showed median Fmax values of 2'328 N. The median Fmax values for the test groups ranged between 1'753 N (Vit) and 2'490 N (Ros). Statistically significant difference was observed among the groups Lis (control) and Vit (KW: p < 0.001). Weibull distribution presented the highest shape values for the group Ros (12.83) and the lowest values for the group Ema (4.71). CONCLUSION: Regarding their load-bearing capacity different pressable lithium disilicates can be recommended to fabricate ultra-thin occlusal veneers on molars when restoring occlusal tooth wear.


Asunto(s)
Cerámica , Litio , Humanos , Soporte de Peso , Ensayo de Materiales , Ámbar , Porcelana Dental , Análisis del Estrés Dental , Diseño Asistido por Computadora
20.
J Conserv Dent ; 25(4): 347-355, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36187858

RESUMEN

Background: Advances in adhesive technologies and escalation in esthetic demands have increased indications for tooth-colored, partial coverage restorations. Recently, material knowledge has evolved, new materials have been developed, and no systematic review has answered the question posed by practitioners: Is the clinical efficacy of resin or ceramic better, for inlay, onlay, and overlay in the long run? Aim: The aim of this systematic review and meta-analysis was to evaluate the clinical performance of ceramic and resin inlays, onlays, and overlays and to identify the complication types associated with the main clinical outcomes. Materials and Methods: Two reviewers (VN and AJ) searched PubMed, Embase, and Cochrane Central registry of controlled trials for published articles between 1983 and 2020 conforming to Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines for systematic reviews. Only clinical studies which met the following criteria were included (1) studies regarding ceramic and resin inlays, onlays, and overlays were included; (2) randomized controlled trials, retrospective or prospective studies conducted in humans; (3) studies with a dropout rate <50% 4) studies with a follow-up higher than 5 years. Results: Of 1718 articles, 21 articles were selected. At 5 years, the estimated survival rates for resin (n = 129) was 86%, feldspathic porcelain (n = 1048) was 90%, and glass ceramic (n = 2218) was 92%; at 10 years, the survival of resin was 75% (n = 115), feldspathic porcelain was 91% (n = 1829), and glass ceramic was 89% (n = 1075). Conclusion: The meta-regression indicated that ceramic partial coverage restorations (feldspathic porcelain and glass-ceramic) outperformed resin partial coverage restorations both at 5-year and 10-year follow-up. When compared between ceramic types, glass ceramics outperformed feldspathic porcelain at 5 years' follow-up and feldspathic porcelain outperformed glass ceramics at 10 years' follow-up. The failures were mostly due to fractures (6.2%), endodontic problems (3%), secondary caries (1.7%), and debonding which was 0.9%.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...